Description
UOL(H) 40 / USL(H) 42 SIL 2
U-ONE Generation II (LWL) – basic unit
System solution U-ONE(-SAFETY)-LWL
- High accuracy thanks to direct gearless mounting to the application shaft plus high resolution (13 bit singleturn / 15 bit multiturn)
- Interference-free signal transmission to the function modules in the switchboard via just one fiber optic cable (up to 1000 m)
- High reliability even when exposed to extreme operating conditions
- Options: Without SIL/PL certification (UOL(H) 40); through hollow shaft, solid shaft for flange or foot mounting, INOX (housing made of V4A / AISI 316), Ex (ATEX / IECEx certification zones 2 and 22)
U-ONE Generation II (LWL) – basic unit
The basic units of the new second-generation universal encoder systems determine and monitor speed and position. They measure the speed and angular position of the application shaft, convert electrical signals into optical signals and transmit them to the (safety) control unit with no interference via fiber optic cable. The compact basic units with an integrated LWL (FOC) transmitter are ideal for mounting onto the shaft because the electronic function modules are stored separately in the switchboard. The units are suitable for use both in new plants and as a modernization solution. Direct mounting requires no additional mechanical components such as distribution gears, distribution couplings or speed increasing gears. The systems are optionally available as certified up to SIL 2 / PL d.
Technical Data
Supply voltage | 15-27 VDC |
Resolution |
|
Switching outputs | Via input/output modules in the switchboard |
Signal outputs/Interfaces | Via controller and communication modules in the switchboard |
Maximum rotation | 2800 rpm |
Electrical connection | Terminal box:
|
Construction type / Ø shafts |
|
Device temperature range | -25 °C to +67 °C |
Degree of protection | IP66 |
Weight | Approx. 3.6 kg |
Device options | Via electronic function modules in the switchboard |
Mechanical options |
|
Special features and certificates | USL(H) 42: SIL 2 (DIN EN 61508); PL d (DIN EN ISO 13849)
ATEX / IECEx (zones 2 and 22) |